contact us

Contact

Please use the form below to get in touch with us.

If you are interested in our company or products, welcome to visit our company and factories; you can also get in contact with us through online customer services, inquiry form, e-mails and telephones. Our engineer will provide prosduct information, specific solution and good service for you as soon as possible.

Address: High-tech Zone, Zhengzhou, China

Email: [email protected]

Equipment

good agitation tank plan

api tank design for agitator load - api (american

api tank design for agitator load - api (american

HI Good morning every one ... but for a thin walled API-650 type tank with a center mounted agitator, a "bridge" is a common solution. ... If you insist on analyzing the roof, plan on a lot of FEA, and probably strengthening the nozzle, roof, roof-to-shell junction and possibly the tank shell itself. With that much weight up high, also check… Read more

take mixing to the max - chemical processing

take mixing to the max - chemical processing

Jul 15, 2003 · Values of 3 to 6 represent medium intensities, and values of 7 to 10 characterize violent agitation. This 1-to-10 agitation scale is based on the impeller pumping capacity divided by the tank cross-sectional area, resulting in a bulk fluid velocity. This velocity, in feet/minute (ft/min.), then is divided by 6 to obtain the scale of agitation… Read more

surface agitation in co2 injected planted tanks - the 2hr

surface agitation in co2 injected planted tanks - the 2hr

Sep 09, 2020 · For many planted tanks, especially smaller ones that are not too tall/narrow, having reasonably good gaseous exchange can simply be done if the flow pattern in the tank exchanged surface layer of water with deeper layers - this usually also provides some surface agitation… Read more

leaching plant design

leaching plant design

Mar 17, 2017 · Design of agitators should provide by-pass lines so any one agitator can be by-passed for maintenance without shutting down the entire circuit. Design the feed and discharge arrangement to minimize short circuiting of the slurry. If feed is introduced at the top of the tank, discharge should be through a riser from the bottom area of the tank… Read more

best management practices for boom spraying | ohioline

best management practices for boom spraying | ohioline

Make sure no leakage is occurring anywhere in the spraying system. Pressure gauges should return to zero when the pressure is off. Check the tank agitation system to make sure the flow to the tank for agitation is sufficient and effective. Check the tire pressure… Read more

[how to] select a motor capacity for agitator - pharma

[how to] select a motor capacity for agitator - pharma

Equate Batch Volume to the basic equation pi/4 x D x D x D., by replacing the Vessel Dia with Equivalent Dia, i.e., V = ( pi/4 ) x Teq x Teq x Teq. Then, Teq = CubthRoot ( 4 x V/pi ) Agitator Dia ( D ) = D/T x Teq. Bulk Velocity ( Vc ) = 6 x Scale of Agitation ft/min. = 0.03048 x Scale of Agitation m/sec… Read more

developing tanks & drums|b&h photovideo

developing tanks & drums|b&h photovideo

Stainless steel tanks are less likely to drip, and thermal capacity decreases, so chemical mixtures aren't as affected by temperature change as they are with plastic tanks. Plastic tanks are cost-effective choices and easy to clean, fill, and empty. Paterson tanks, a popular plastic option for beginners… Read more

burning problem in hard anodizing of aluminum

burning problem in hard anodizing of aluminum

Oct 13, 2020 · A. Hard coat temps in the 32 °F range, and very very good solution agitation are extremely important. We run at 30 ASF for hard coat. When the agitation was not sufficient, the aluminum racks as well as some parts would burn. Get a good rolling solution. I would bet that's where your problem is. Todd Huehn - Blaine, Minnesota, USA… Read more

agitation- an overview | sciencedirect topics

agitation- an overview | sciencedirect topics

Vertical shaft paddle type stirrers should have a diameter and paddle height greater than two thirds of a plan dimension and should have 500 mm clearance to the walls. For good performance, horizontal shaft type stirrers should be mounted in sinuous channels to reduce short-circuiting and should have at least three paddles on each diametrical arm… Read more

atank agitationsystem is useful for most sprayable

atank agitationsystem is useful for most sprayable

Sep 08, 2019 · tank mixing/agitation nozzles - bete spray nozzlesin many applications it is necessary to keep tank contents mixed or agitated to . and submerged spray nozzles, greatly reducing system complexity, capital cost, and . even after liquids are combined, mixing nozzles can be used to agitate the.airblast agitation and filling . sprayers 1012 jan 2020 . consequently, good agitation is very …… Read more

take mixing to the max- chemical processing

take mixing to the max- chemical processing

Jul 15, 2003 · Values of 3 to 6 represent medium intensities, and values of 7 to 10 characterize violent agitation. This 1-to-10 agitation scale is based on the impeller pumping capacity divided by the tank cross-sectional area, resulting in a bulk fluid velocity. This velocity, in feet/minute (ft/min.), then is divided by 6 to obtain the scale of agitation… Read more

spray equipment and calibration— publications

spray equipment and calibration— publications

Replace the agitator nozzle with one having a larger orifice if the pressure will not come down to the desired point. Use a smaller agitation nozzle if insufficient agitation results when spraying pressure is correct and the pressure relief valve is closed. This will increase agitation and permit a wider open control valve for the same pressure… Read more

lateral agitation? | photo.net photography forums

lateral agitation? | photo.net photography forums

Jan 28, 2016 · Continuous rotary rotation works very well. There is no reason turning the tank a few turns for each agitation cycle will not work BUT the tank needs to be turned an equal number of turns in each direction to minimize/eliminate streaks from rotation. I rotate my 135/120 tank 2 turns at the end of each inversion cycle changing directions each cycle… Read more

does small chrome platingtankneed push-air &agitation?

does small chrome platingtankneed push-air &agitation?

Does Small Chrome Plating Tank Need Push-Air & Agitation? 2004. Q. I plan to set-up a chrome plating shop soon. The main tank is 2' x 1' wide x 3' deep. The workpiece is typically 1" x 2" x 6" length plate 1 at a time. Two questions:-1) Do I need a push-pull exhaust system? If so, what volumetric rate of exhaust? What push and pull air velocity?… Read more

agitators- chemineer, inc

agitators- chemineer, inc

Agitators can be mounted on beams/channels, clamp mounted to the tank side, or flange mounted to the vessel with a variety of sealing options. SB Side Entry Agitators The SB agitator is a belt-driven unit with features engineered for side entry agitator service… Read more

adjusting, maintaining and cleaning airblast sprayers

adjusting, maintaining and cleaning airblast sprayers

With agitation on, circulate a 50% solution of water and automotive antifreeze with rust inhibitor throughout the lines for 5 minutes and drain it through the plumbing system (not the booms). If required, drain and flush crankcase and refill with new oil… Read more

agitator design and selection- slideshare

agitator design and selection- slideshare

Agitator design and selection 1. Agitator Design and Selection Standard Engineers [email protected] 2. Food for Thought You wanted to STIR THINGS UP But, your MIXING gave only ‘AGITATION’. There’s many a slip between the Plant and the Lab… Read more

tank mix compatibility| sprayers 101

tank mix compatibility| sprayers 101

Tank mixing adjuvants. Adjuvants are outside the scope of Canada’s federal policy on unlabeled tank mixes. The label for at least one tank mix partner must specify the use of an adjuvant, and only registered adjuvants labeled for the crop and for tank mixing are permitted… Read more