contact us

Contact

Please use the form below to get in touch with us.

If you are interested in our company or products, welcome to visit our company and factories; you can also get in contact with us through online customer services, inquiry form, e-mails and telephones. Our engineer will provide prosduct information, specific solution and good service for you as soon as possible.

Address: High-tech Zone, Zhengzhou, China

Email: [email protected]

Equipment

agitation tank level

[how to] select a motor capacity for agitator - pharma

[how to] select a motor capacity for agitator - pharma

If Scale of Agitation is 3, then the effect of agitation is Normal, this is most probably used for the Dryer's. If Scale of Agitation is 6, then the effect of agitation is Vigorous, this means the mass that need to be stirred is somewhat denser but the bulk density will be not much… Read more

best practices for low volume mixing in reactors

best practices for low volume mixing in reactors

while vessel level is decreasing, the agitator speed must be slowed while the liquid drops to 8-10” above the blade level. In the case of filling a vessel, it is generally okay to start and run the agitator during filling, provided that the filling is done quickly, and the liquid level is not held at blade level… Read more

agitator speed - an overview | sciencedirect topics

agitator speed - an overview | sciencedirect topics

A gate type anchor agitator is shown in Figure 5.6.Anchor agitators operate within close proximity to the tank wall. The shearing action of the anchor blades past the tank wall produces a continual interchange of liquid between the bulk liquid and the liquid film between the blades and the wall [Holland and Chapman (1966)].Anchors have successfully been used to mix liquids with dynamic… Read more

level measurement in a closed tank using a differential

level measurement in a closed tank using a differential

Minimum = level at 0% = HP (SGp * h0) – LP (SGs * h) Maximum = level at 100% = HP (SGp * H) – LP (SGs * h) HP = high pressure; LP = low pressure; SGp =Specific gravity of the process; SGs =Specificgravity of seal; H = max. level height; h0 = min. level height; h = height of full tank; The one with the electronic sensor… Read more

back to basics: effect of d/t ratio on agitator power for

back to basics: effect of d/t ratio on agitator power for

We choose a 20 foot diameter flat bottomed tank, with a 20 foot liquid level, giving us a volume of 47000 gallons or 178000 liters. The fluid in the tank could be a starch slurry, a dry grind corn slurry or other grain slurry common in the ethanol industry (but not cellulosic unless full hydrolysis has occurred), with a specific gravity of 1.2 and a viscosity of less than 50 cP, which will result in turbulent flow… Read more

pumps vs.agitators for tank mixing, classiccase of capex

pumps vs.agitators for tank mixing, classiccase of capex

May 04, 2014 · The tank size is 198” (5.03m) diameter, shallow bottom, with a working volume of 40,800 gallons (154 m 3). Tank contents have an average specific gravity of 1.0. Pump Description. Installed on the above tank is a pump-around loop with two tangential nozzles. The pump produces a flow rate of 524 GPM (0.033 m 3 /s), and has a 15 Hp (11kW) motor. It is a simple centrifugal pump… Read more

reactors- processdesign

reactors- processdesign

Feb 22, 2016 · The selection chart given in Figure 6 can be used to make a preliminary selection of the agitator type, based on the liquid viscosity and tank volume (Towler and Sinnott, 2013). Figure 5. Low-speed agitators (Towler and Sinnott, 2013) Figure 6. Agitator selection guide (Towler and Sinnott, 2013) Gas-Liquid Mixing… Read more

gold leaching agitation tanks

gold leaching agitation tanks

Mar 17, 2017 · Dilution during agitation varies from 1 of solution to 1 of solids by weight to 3 of solution to 1 of solids, occasionally higher, probably averaging 2 to 1. Operation is continuous through a series of agitators, preferably three or more, to minimize any …… Read more

surface agitation: stir, churn and oxygenate your aquarium

surface agitation: stir, churn and oxygenate your aquarium

Apr 07, 2021 · Well, for planted tank owners who are injecting CO 2 into the water, that isn’t necessarily a good thing – you want the CO 2 to stay in the water, not leave it. If you are injecting CO 2 into your tank, you want to reduce agitation down to a gentle ripple – so that you are not wasting CO 2. How do you agitate the water in your aquarium?… Read more

what is surfaceagitation? why is it so important?

what is surfaceagitation? why is it so important?

Surface agitation occurs by simply pumping air into the tank’s water. Utilizing some form of an aeration system, air must be pumped into the water until bubbles rise and burst at the surface. The consistent bursting of air bubbles immediately breaks the water’s surface tension, and thus surface agitation …… Read more

levelmeasurement of liquids | radarlevelsensors from

levelmeasurement of liquids | radarlevelsensors from

Level measurement in the preparation tank for solvents. ... Foaming, agitator. Cargo tank in a bitumen tanker. Level measurement and point level detection in the cargo tanks of a bitumen tanker. Bitumen is transported at temperatures of around 170 °C to 190 °C. The heating is supplied via an array of multi-layered heating tubes mounted on the… Read more

agitators- chemineer, inc

agitators- chemineer, inc

Agitators can be mounted on beams/channels, clamp mounted to the tank side, or flange mounted to the vessel with a variety of sealing options. SB Side Entry Agitators The SB agitator is a belt-driven unit with features engineered for side entry agitator service… Read more

agitationscaleup calculation

agitationscaleup calculation

Agitation Scaleup Calculation Does the scaleup from smaller to larger scale based on criteria like equal tip speed, power per unit volume, equal Reynold's number, equal shaft speed… Read more

collection and reception ofmilk| dairy processing …

collection and reception ofmilk| dairy processing …

The agitator stops if the level in the tank drops below the electrode. This electrode is known as the low-level indicator (LL). Overflow protection. A high-level electrode (HL) is fitted at the top of the tank to prevent overfilling. This electrode closes the inlet valve when the tank is full, and the milk supply is switched to the next tank… Read more

tankgauges |mcmaster-carr

tankgauges |mcmaster-carr

Horizontal-Mount Fuel-Level Gauges for Tanks. Mount these gauges on the flat end of a horizontal, cylindrical tank to monitor diesel fuel, fuel oil, or gasoline level. Precision Liquid-Level Gauges for Tanks. For precise measurement of water, hydraulic fluid, or diesel fuel level, this gauge provides level …… Read more

agitatorpower requirement - checalc

agitatorpower requirement - checalc

Scale of Agitation 1 is quite mild, 3 is normal, 6 is vigorous and 10 is violent. Scale of 1 to 2 Characteristic of application requiring minimum fluid velocities to produce a flat but moving fluid batch surface. Scale 2 agitation will blend miscible fluids with specific gravity differences less than 0.1 and viscosity ratio of …… Read more

tank level-1 - war brokers wiki | fandom

tank level-1 - war brokers wiki | fandom

The Level 2 Tank is based on the Russian T-72 main battle tank. The Level 3 Tank is based on the American M1A1 Abrams main battle tank (or MBT-80) Tanks used to be immune to bullets, but this was later changed. Doing missions involving a tank will guarantee an item box for the tank used in the mission. There is a “Level 4” Anti Aircraft… Read more

capacitance levelmeasurement | endress+hauser | endress

capacitance levelmeasurement | endress+hauser | endress

Particularly in small tanks and build-up forming media. Point level detection works with Liquicap, Liquipoint, Minicap or Solicap capacitance level switches also in applications involving aggressive media and heavy build-up in liquids and solids. Check out the broad range of capacitance level sensors and click on the button below… Read more

tank liquid agitation indicator | delta mcorp

tank liquid agitation indicator | delta mcorp

It is often desirable to monitor the level of a liquid in a process tank or vessel. In addition to the level of the fluid, a dual channel sensing switch can also be configured to indicate when agitation is taking place in the tank (i.e. stirring action). Application Solution: A level switch with dual channels has the capability of setting two discrete liquid level interaction set points. Normally the first channel would be set for a …… Read more